Troubleshooting
At Squair we make it easy to access everything you need. Its all infront of you without even looking.
At Squair we make it easy to access everything you need. Its all infront of you without even looking.
This section outlines common issues that may be encountered during operation of your Squair Air Suspension system, along with possible causes and recommended actions. Always perform inspections with the vehicle safely parked on level ground.
Possible Causes
Loose or improperly sealed air fittings
Damaged or pinched air line
Leak at cup or fitting connection
Recommended Action
Re-pressurise the system and inspect all fittings and connections using a soap and water solution
Tighten fittings as required (do not overtighten)
Replace any damaged air line and reroute to prevent rubbing or strain
Possible Causes
Uneven air pressure between cups
Air leak on one side of the system
Binding suspension components
Recommended Action
Inspect both sides of the suspension for leaks
Verify air lines are free from kinks or obstructions
Check that all suspension components move freely
Possible Causes
Compressor not receiving power
Blown fuse or poor ground connection
Loose wiring connection
Recommended Action
Check all electrical connections against the wiring diagram
Inspect fuses and relays
Ensure the compressor ground is connected to bare metal
Possible Causes
Small air leak in the system
Insufficient tank pressure retention
Moisture buildup affecting system efficiency
Recommended Action
Inspect the entire system for leaks using soap and water
Drain any moisture from the air tank if applicable
Do not continue operating the system if excessive run time persists
Possible Causes
Restricted air line
Contaminants or debris in fittings
Low system voltage
Recommended Action
Inspect air lines for bends, pinches, or obstructions
Ensure battery voltage and charging system are operating correctly
Clean or replace affected fittings if required
Possible Causes
Air leak under pressure
Loose mounting hardware
Compressor mounting vibration
Recommended Action
Inspect all fittings and lines for leaks
Check mounting bolts and brackets for proper torque
Ensure compressor and components are securely mounted with isolation where required
If an issue cannot be identified or resolved using the steps above, discontinue use immediately and contact Squair Air Suspension or a qualified installer. Continued operation with a fault may result in component damage, vehicle damage, or personal injury.